Product Detail
126 Zahn Cup
Model : 126

Product Description

ESG 126 Zahn Cups can be used to quickly measure the viscosity of liquids such as Paint, Ink, Varnishes, Syrup and Oil. They are produced according to ASTM D 816, ASTM D 1084, and ASM D 4212. The Stainless Steel Cups are molded precisely and the orifices are precision drilled using high-speed CNC drilling.

Each cup has a 12-inch loop handle to allow the cup to be dipped by hand into a liquid container.  At the center of this handle is a finger-ring for holding the cup in a vertical position during use. Their orifice diameters are set at the factory for appropriate results with applicable NIST traceable Newtonian oils.


It is done by filling up the volume of Zahn Cup with the required liquid and then placing an index finger over the orifice to stop any flow out of the liquid. A ring at the Zahn Cup handle allows the cup to be hanged perpendicularly(still with the finger stopping any liquid flow out). Prepare a Digital stopwatch and set zero. Immediately start the stopwatch when the finger is released. As soon as there is a first “break” of the flow, stop the stopwatch. The second shown is the time of the liquid flow, which is also the flow viscosity of that liquid.

Every Zahn cup has its own coefficient “K”, which is marked on the cup body.

                                                      Fact Viscosity=Testing viscosity × K


Technical Parameters

Volume of Cup:44ml                                

Length of Handle:40±0.1mm                    

Height of Cup:58±0.1mm                        
Measurement Temperature:25°C±1°C  


Specifications

Details/Zahn cup

Zahn cup 1#(ESG126/1)

Zahn cup 2#(ESG126/2)

Zahn cup 3#(ESG126/3)

Zahn cup 4#(ESG126/4)

Zahn cup 5#(ESG126/5)

Orifice(cm/inches)

1.98/0.08

2.74/0.11

3.76/0.15

4.27/0.17

5.28/0.21

Zahn Range (sec)

33.5-80

20-80

20-75

20-80

20-80

Centistokes Range

5-56

21-231

146-848

222-1110

460-1840

Applications

Very Thin Oil

Thin Oil,Paint
Lacquer

Medium Oil
Mixed Paint

Viscous Liquid and Mixtures

Very Viscous Mixtures

Ordering Information

ESG 126/1

ESG 126/2

ESG 126/3

ESG 126/4

ESG 126/5


Attentions

Both the Zahn Cups and the Iwata Cup are based on measuring the Flow of liquid in seconds. Hence, a precision stopwatch is required.

Results should be reported in Zahn-Seconds at a specified temperature for a particular cup. To convert Zahn-Seconds to centistokes, refer to ASTM D4212, D816, and D1084

                                                                 Centistokes ×Specific Gravity= Centipoise



Service On-line
 
 
 Contact Details
Hotline:+86-754-88811959
Email:esgsales68@esgprinting.com